User's Manual

64
RIOTRONIC X+
User Manual
7.9. Restarting the device
In case if device hangs, it could be restarted by pressing and holding any three keys (except
ON/OFF) for longer than 4 seconds.
7.10. Troubleshooting
Problem Possible cause Action
Blaster won’t start Very low batter level Connect battery charger
Error “OPEN LINE
Bus line or detonator is
disconnected
Connect Bus line or detonator and try
again
Error “SHORT LINE” Bus-line is shorted
Remove the short circuit and try
again
Error “PIN ERROR” Entered PIN is incorrect Try to enter user or admin PIN again
NFC transfer won’t start NFC antennas are not aligned
NFC sending and receiving antennas
must be precisely aligned
7.11. Technical specification
Parameter Value
Dimensions 300 x 249 x 119 mm
Operation temperature -15°C ÷ +55°C
Charging temperature 0°C ÷ +40°C
Storage temperature -20°C ÷ +50°C
Charging supply voltage 10÷12 V DC
Battery voltage 7,2V
Battery capacity 20,8Ah
Battery type Li-Ion
Display type LCD
Display size 3,5”
Display resolution 320x480