Datasheet

Copyright 2005 - 2021 MaxBotix Incorporated Patent 7,679,996
I2CXL-MaxSonar
®
- EZ Series
Page 1
Web: www.maxbotix.com
PD11848k
MaxBotix Inc., products are engineered and assembled in the USA
Notes:
1
See Close Range Operation
2
Users are encouraged to evaluate the sensors
performance in their application
3
By design
4
Recommended time between readings of
100ms (10Hz Rate)
5
Please reference page 6 for minimum
operating voltage verses temperature
information.
6
Please reference page 19 for part number key.
Features
I2C bus communication allows rapid
control of multiple sensors with only
two wires
High acoustic power output
Real-time auto calibration and noise
rejection for every ranging cycle
Calibrated beam patterns
Continuously variable gain
Object presence information as close
as 1-mm from the sensor. Range
information starting at min. distance.
3V to 5.5V supply with very low
average current draw
Readings can occur up to every 25mS
(40Hz rate)
4
for up-close objects.
15Hz rate for full range.
Triggered operation provides a new
range reading as desired
Ultrasonic signal frequency of 42KHz
Status pin available to determine
sensor state
Power-up address reset pin available
Physical dimensions match other
XL-MaxSonar-EZ products
Operational temperature from
0°C to +65°C (32F to +149F)
5
Low Power Requirement
Wide, low supply voltage
requirements eases battery powered
design
Low current draw reduces current
drain for battery operation
Fast first reading after power-up
eases battery requirements
Benefits
Acoustic and electric noise resistance
Reliable and stable range data
Low cost
Quality controlled beam
characteristics
Very low power rangefinder,
excellent for multiple sensor or
battery based systems
Ranging is triggered externally
Fast measurement cycle
No power up calibration required
Perfect for when objects may be
directly in front of the sensor during
power up
Easy mounting
Applications and Uses
Multi-sensor arrays
Proximity zone detection
People detection
Robot ranging sensor
Autonomous navigation
Educational and hobby robotics
Environments with acoustic and
electrical noise
Distance measuring
Long range object detection
Security systems
Motion detection
Landing flying objects
Collision avoidance
Bin level measurement
Close Range Operation
Applications requiring 100% reading-to-reading reliability should not use MaxSonar sensors at a distance closer than
20cm. Although most users find MaxSonar sensors to work reliably for detecting objects from 0 to 20cm in many
applications, MaxBotix
®
Inc. does not guarantee operational reliability for objects closer than the minimum reported
distance. Because of ultrasonic physics, these sensors are unable to achieve 100% reliability at close distances.
______________________________________________________________________________________________________________________________________
Warning: Personal Safety Applications
We do not recommend or endorse this product be used as a component in any personal safety applications. This product
is not designed, intended or authorized for such use. These sensors and controls do not include the self-checking
redundant circuitry needed for such use. Such unauthorized use may create a failure of the MaxBotix
®
Inc. product which
may result in personal injury or death. MaxBotix
®
Inc. will not be held liable for unauthorized use of this component.
I2CXL-MaxSonar
®
- EZ Series
High Performance Sonar Rangefinder
MB1202, MB1212, MB1222, MB1232, MB1242
6
The I2CXL-MaxSonar-EZ series offers industrial ultrasonic sensors with an easy to
use I2C interface. These sensors have a high acoustic power output along with
real-time auto calibration for changing conditions (voltage and acoustic or electric
noise) that ensure users receive the most reliable (in air) ranging data for every reading taken. The low power
3V 5.5V operation provides very short to long-range detection and ranging, in a compact form factor. The
I2CXL-MaxSonar-EZ detect objects from 0-cm* to 765-cm (25.1 feet) and provide sonar range information
from 20-cm or 25-cm out to 765-cm with 1-cm resolution. Objects from 0-cm* to minimum distance typically
range as minimum distance.
1
(*Objects from 0-mm to 1-mm may not be detected).
1
See Close Range Operation

Summary of content (21 pages)