ER Lithium Thionyl Chloride Battery (Li/SOCI2) With Terminals and Wire Connectors (ER18/50 / ER17/50 / ER6 / ER6C / ER17/33 / ER3 / ER3S) LITHIUM THIONYL CHLORIDE BATTERY
Safety Instructions This battery is a high energy density sealed battery containing dangerous (Lithium) and deleterious (Thionyl Chloride) materials. For this reason, improper handling of the battery could lead to distortion, leakage*, overheating, explosion, fire, or generation of irritating/corrosive gases, causing bodily injury or equipment trouble. Please observe the following instructions to prevent accidents.
ER Lithium Thionyl Chloride Battery Storage Avoiding storing the battery in direct sunlight, or in excessively hot and humid locations, and store it out of the way of rainwater and other adverse environmental elements. Using and setting protective resistors A protective resistor is used to Maximum Current Type prevent the battery from being 125µA ER18/50 charged by large surges of current 125µA ER17/50 during diode failure.
LITHIUM THIONYL CHLORIDE BATTERY The ER battery is for industrial use only. When replacement is necessary, please contact the manufacturer of your equipment. Overview This battery is ideal for such long-term applications as power for electronic devices and electric power, water, and gas meters, and especially as a backup power source for memory ICs. Products Model ER18/50 ER17/50 ER6 ER6C ER17/33 ER3 ER3S 3.6 3.6 3.6 3.6 3.6 3.6 3.
ER Lithium Thionyl Chloride Battery Minimum transient voltage The lithium thionyl chloride battery has remarkably lower self-discharge when compared with conventional batteries. This is because a lithium chloride membrane is formed over the negative lithium surface, blocking reaction with the positive material. When first discharging after storage, resistance from this lithium chloride membrane may temporarily reduce the voltage at the initiation of discharge.
LITHIUM THIONYL CHLORIDE BATTERY ER18/50 (3650mAh) Relationship between Discharge Current and Duration Time Discharge Characteristics 1,000,000 Temperature: 20 deg. C 4.0 3.0 Discharge duration time (h) Voltage (V) 3.5 2.5 2.0 1.5 10 120 A 1.2mA 102 103 104 Discharge duration time (h) 24 A 105 106 Temperature: –40 deg. C Voltage (V) 4.0 Year 10 100,000 70,000 50,000 20,000 60 deg. C 1 0.5 2,000 3.0 1,000 10 20 30 102 120 A 103 104 1000 Discharge current: 1.
ER ER6 Lithium Thionyl Chloride Battery (2000mAh) Discharge Characteristics Relationship between Discharge Current and Duration Time Temperature: 20 deg. C 4.0 100,000 10 7 Year 50,000 3.0 Discharge duration time (h) Voltage (V) 70,000 2.0 1mA 1 102 10 103 100µA 20µA 104 105 Discharge duration time (h) Temperature: –40 deg. C 4.0 5 4 3 20,000 20 deg. C 2 60 deg. C 10,000 1 7,000 5,000 0.5 Voltage (V) 2,000 3.
LITHIUM THIONYL CHLORIDE BATTERY ER17/33 (1600mAh) Discharge Characteristics Relationship between Discharge Current and Duration Time Temperature: 20 deg. C 10 7 70,000 50,000 3.0 2.0 800 A 1 102 10 80 A 103 104 16 A 105 Discharge duration time (h) Temperature: –40 deg. C 4.0 Voltage (V) Year 100,000 Discharge duration time (h) Voltage (V) 4.0 5 4 3 20,000 10,000 1 7,000 60 deg. C 5,000 0.5 2,000 3.0 1,000 20 30 50 70 100 200 300 500 Discharge current ( A) 2.
ER ER3S Lithium Thionyl Chloride Battery (790mAh) Relationship between Discharge Current and Duration Time Discharge Characteristics Temperature: 20 deg. C 100,000 3.0 Discharge duration time (h) Voltage (V) 4.0 2.0 400µA 1 10 102 103 40µA 104 8µA 105 Discharge duration time (h) Temperature: –40 deg. C Voltage (V) 4.0 70,000 10 7 Year 50,000 5 4 2 20 deg. C 10,000 1 7,000 60 deg. C 5,000 0.5 2,000 3.0 1,000 8 10 30 50 70 100 200 300 500 Discharge current (µA) 2.
With Terminals and Wire Connectors LITHIUM THIONYL CHLORIDE BATTERY External Dimensions (unit : mm) 0.25 0.75 0.75 0.75 (–) 6.5 6.5 7.5 ER6C WKP 8.5 11.5 ER6C #2 PC(2) ø14.5 44.5 6.0 1(+) 2(–) 15.2 0.25 52 (51) 53.0 (+)1 (–)2 Plastic cap Insulation sleeve 45.0 (+) Loop Hook 3.5 ø0.63 7.5 100 18 57.3 (53.5) 54.7 ø14.5 47.6 (52.6) ø17 (–) ER6K-#17 ø0.63 7.5 (+) 0.25 53.8 47.7 ø18 ø0.63 6.5 (+) (53.6) 53.8 6 47.7 ER6 #2 PC ER17/50 #2 PC ø0.
Hitachi Maxell, Ltd. 2-18-2, Iidabashi, Chiyoda-ku, Tokyo 102-8521 Japan Tel: (+81) 3-3515-8249 Fax: (+81) 3-3515-8305 Visit our website at: www.maxell.com NORTH AMERICA / SOUTH AMERICA Maxell Latin America Maxell Corporation of America Plaza Btesh - Calle 50, Panama City, Main Office: Panama 22-08, Route 208 Fair Lawn, NJ Tel: (+507) 269-6737 07410, U.S.A. Fax: (+507) 263-4413 Tel: (+1) 201-794-5900 E-mail: maxell@ciabtesh.