Operation Manual

In AUTO mode,the indicator default temperature is 24 .
AUTO mode operation procedure
Operates by selecting automatically the operation mode(HEAT,DRY,COOL)depending on the room temperature at starting.
With the remote controller pointing towards the air conditioner.With the remote controller pointing towards the air conditioner.
Press the ON/OFF button.
1
When the unit is not at AUTO mode:When the unit is not at AUTO mode:
2
Press the MODE select button.
Move the MODE to the (AUTO)position.
To Stop:
Press the ON/OFF button.
The operation of the AUTO
mode can be performed by
only pressing the ON/OFF
button from the next time.
Air is not blown out at during opera-
tion.
NOTE
If you don't like the content of AUTO mode operation,
change to HEAT,DRY or COOL than AUTO.
If you don't like the content of AUTO mode operation,
change to HEAT,DRY or COOL than AUTO.
Temperature adjusting procedure during AUTO operation
Air temperature adjustment is possible even during automatic operation.There are 6 levels of adjustment possible with
the button or the button .
Press the or button.
1
When the button or the button is pushed ,the indicator does not change.
ON/OFF
CLOCK
RESET
HR.
MIN.
6
Power cord is to be selected according to national regulations.
Outdoor unit power cord should be selected and connected according to the outdoor unit
installation manual.
Wiring should be away from high temperature components, or the insulation layer of the
wires may melt down.
Use wire clamp to fix the wires and terminal block after connection.
Control wire should be wrapped together with heat insulated refrigerant pipes.
Connect the indoor unit to power only after the refrigerant has been vacuumed.
CAUTION
Don t connect the power wire to the signal wire connection end.
Indoor/Outdoor Unit Signal Wire
Connect the wire according to their numbers.
Wrong connection may cause malfunction .
Wiring Connection
Seal the wiring connection with the insulation material , or the condensing dew will be caused.
Wiring specifications are listed below, insufficient capacity would over-heat the wire or destroy
the machine.
23
24000Btu/h 36000Btu/h SIGNAL WIRING DIAGRAM
24000Btu/h 36000Btu/h 42000Btu/h, 48000Btu/h SIGNAL WIRING DIAGRAM
*
ON/OFF
CLOCK
RESET
HR.
MIN.
2
1
18000Btu/h SIGNAL WIRING DIAGRAM
12000Btu/h SIGNAL WIRING DIAGRAM