User's Manual
MaxID RM100 RFID reader interface
Project - RFID ID1170 Version 0.1 18 October, 2005 Page 23 of 24
I9 EPC at 868 MHz with FCC timings
D RF Power down
U RF Power up
H Hopping (0 to disable) (255 hopp enable) (1-50 ch selectable)
J Hopp speed (-1 to read) (20 default) (10-200 in mS steps)
F Filter repeatable tags (1-9) seconds. 0 to disable
R Read tag once
RR Read tag continuously
Wdata Write tag with \"data\"
Pval Set output power (0 to 255)
Qnvalue Write value (0 to 255) to FPGA port n (0 to B)
9 Show Q-values
V Get version
^L Loader
^C Reboot
When tags are read, they are reported in the following fashion:
I123456789ABCDEF0 for IPX tags
E123456789ABCDEF012345678 for EPC Class 1 tags
U123456789ABCDEF0123456789ABNCDEF0 for EPC 1.19 1 tags
8.2.3 Evaluation program