Owner's manual

6612_OMU_S2_URT_V1_13 Firmware Description Document FDD_6612_010
22 Rev. 1.1
Output
Location
(hex)
LSB Comment Example
Bit 14 MAXIB_WB maximum
wideband current exceeded on
Outlet 2.
Bit 15 PFB_NB negative
Narrowband Power Factor Negative
Threshold Alarm for Outlet 2.
Bit 16 PFB_NB positive
Narrowband Power Factor Positive
Threshold Alarm for Outlet 2.
Bit 17 PFB_WB negative
Wideband Power Factor Negative
Threshold Alarm for Outlet 2.
Bit 18PFB_WB positive
Wideband Power Factor Positive
Threshold Alarm for Outlet 2.
Bit 19 MAXIT_WB maximum
total wideband current exceeded on
both Outlet 1 and Outlet 2.
Bit 20 MAXIT_NB
maximum
total narrowband current exceeded
on both Outlet 1 and Outlet 2.
Bit 21 CREEP A Alert Creep
Alert on Outlet 1.
Bit 22 CREEP B Alert Creep
Alert on Outlet 2.
Bit 23 Line/Neutral Reversal
detected.
Bit 24 Reserved.
Bit 25 Reserved.
Bit 26 Unexpected Reset.
Bits 27-31 Reserved.
Note: Duplicate of address 0x02
(see Table 2)
Irms_wb A
Overcurrent
Event Count
23
Counter increments on each edge
event.
If four wideband over current
events have occurred on Outlet 1:
)23?<CR>
Returns: +4
Vrms Under
Voltage
Event Count
24
Counter increments on each edge
event.
Note: Duplicate of address 0x04
(see Table 2).
If four under voltage events have
occurred:
)24?<CR>
Returns: +4
Vrms Over
Voltage
Event Count
25
Counter increments on each edge
event.
Note: Duplicate of address 0x06
(see Table 2).
If four over voltage events have
occurred:
)25?<CR>
Returns: +4
Vrms A 26 mV
Vrms voltage
Note: Duplicate of address 0x06
(see Table 2).
If the line voltage is 120 V
)26?<CR>
Returns:
+120.000
Watts A 27 mW
Outlet 1 active power
measurement (per second).
Note: Duplicate of address 0x07
(see Table 2).
If 120 Watts are measured on
Outlet 1
)27?<CR>
Returns:
+120.000