Manual

UG_6613_ 060 6613_OMU_2+2S_URT_V1_00 Firmware Description Document
Rev. 1.1 7
4 Command Line Interface
The 6613_OMU_2+2S_URT_v100 firmware implements an instruction set called the Command Line
Interface (CLI), which facilitates communication via UART between the 78M6613 and the host processor.
4.1 Identification and Information Commands
The I command is used to identify the revisions of the 6613_OMU_2+2S_URT_v100 firmware code and
the embedded CE code. The host sends the I command to the 78M6613 as follows:
>I<CR>
The 78M6613 will reply the following:
TSC 78M6613 OMU 2+2S URT V1.00, Nov 05 2010(c) 2010 Teridian Semiconductor Corp.
All Rights Reserved
CEVIVI200F0
>
4.2 Reset Commands
A soft reset of the 78M6613 can be performed by using the Z command. The soft reset restarts code
execution at addr 0000 and does not alter flash contents. To issue a soft reset to the 78M6613, the host
sends the following:
>Z<CR>
The W command acts like a hardware reset. The energy accumulators in XRAM will retain their values.
Z Reset
Description: Allows the user to cause soft resets.
Usage: Z Soft reset.
W Simulates watchdog reset.