User guide

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040
20 Rev. 1.0
Output
Location
(hex)
LSB Comment Example
Vrms Under
Voltage
Event Count
24
Counter increments on each edge
event.
If four under voltage events have
occurred:
)24?<CR>
Returns: +4
Vrms Over
Voltage
Event Count
25
Counter increments on each edge
event.
If four over voltage events have
occurred:
)25?<CR>
Returns: +4
Vrms A 26 mV Vrms voltage
If the line voltage is 120 V
)26?<CR>
Returns:
+120.000
Watts A 27 mW
Active power measurement (per
second).
If 120 Watts are measured
)27?<CR>
Returns:
+120.000
Wh A 28 mWh
Active accumulated energy
measurement (per hour).
If 120 Wh are measured
)28?<CR>
Returns:
+120.000
Total Cost A 29 mUnits Cost of Wh A.
If the cost is 102.536 units
)29?<CR>
+102.536
Irms A 2A mA rms current measurement.
If current measured
is 12 Amps
)2A?<CR>
Returns:
+12.000
VARs A 2B mW
Reactive power measurement (per
second).
If 120 VARs
are measured
)2B?<CR>
Returns:
VAs A 2C mW
Apparent power measurement (per
second).
If 120 VAs
are measured
)2C?<CR>
Returns:
+120.000
Power
Factor A
2D
Power factor. The output will be
between -0.950 and 1.000.
Positive power factor is defined as
current lagging voltage (inductive).
Negative power factor is defined as
voltage lagging current
(capacitive).
If the power factor
is 0.95
)2D?<CR>
Returns:
+0.950
Phase
Angle A
2E
Phase angle. The output will be
between 180.000 and -180.000.
If the phase angle measured is 60
degrees
)2E?<CR>
Returns:
+60.000