User guide

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040
22 Rev. 1.0
Output
Location
(hex)
LSB Comment Example
VAs A Max 39 mW
Maximum apparent power
measured (per second).
If the largest VAs measured
is 300 VARs
)39?<CR>
Returns:
+300.000
Power
Factor A Min
3A
Minimum power factor measured.
Minimum is defined as the most
negative or least positive number.
If minimum power factor measured
is 0.6
)3A?<CR> Returns:
-0.600
Power
Factor A
Max
3B
Maximum power factor measured.
Maximum is defined as the most
positive or least negative number.
If maximum power factor measured
is 0.9
)3B?<CR> Returns:
+0.900
Phase
Angle A Min
3C
Minimum phase angle measured.
If the minimum phase angle
measured is 10 degrees
)3C?<CR>
Returns:
+10.000
Phase
Angle A Max
3D
Maximum phase angle measured.
If the maximum phase angle
measured is 70 degrees
)3D?<CR>
Returns:
+70.000
Reserved 3E
Reserved
Reserved
Reserved 3F
Reserved
Reserved