71M6513/71M6513H
3-Phase Energy Meter IC
DATA SHEET
SEPTEMBER 2011
© 2005-2011 Teridian Semiconductor Corporation Page: 73 of 104
A Maxim Integrated Products Brand
CE
Address
Name Default Description
0x11 TEMP_NOM 0
During calibration, the value of TEMP_RAW_X should be placed in
TEMP_NOM.
0x30 DEGSCALE 22721
Scale factor for TEMP_X.
TEMP_X = -DEGSCALE*2
-22
*(TEMP_RAW_X-TEMP_NOM).
0x38 EXT_TEMP 0
Should be 15 or 0. When 15, causes the CE to ignore internal temperature
compensation and permits the MPU to control GAIN_ADJ. When internal
temperature compensation is selected, GAIN_ADJ will be:
+
++=
23
2
14
2
2_
2
_
116384_
PPMCXTEMPPPMCXTEMP
floorADJGAIN
Default is 0 (internal compensation).
0x39 PPMC 0
Linear temperature compensation factor. Equals the linear temperature co-
efficient (PPM/°C) of VREF multiplied by 26.84, or TC1 (expressed in µV/°C,
see Electrical Specifications) multiplied by 22.46
1
. A positive value will cause
the meter to run faster when hot. The compensation factor affects both V and
I and will therefore have a double effect on products.
1
CE scaling factor 22.46=2
21
/(1.195*5
7
)
0x3A PPMC2 0
Square-law temperature compensation factor. Equals the square-law tem-
perature coefficient (PPM/°C
2
) of VREF multiplied by 1374, or TC2 (ex-
pressed in µV/°C
2
, see Electrical Specifications) multiplied by 1150
2
.1. A po-
sitive value will cause the meter to run faster when hot. The compensation
factor affects both V and I and will therefore have a double effect on prod-
ucts.
2
CE scaling factor 1150=2
29
/(1.195*5
8
)
Output variables: TEMP_X is the temperature measurement from reference temperature of TEMP_NOM. TEMP_X is
computed using TEMP_RAW_X and DEGSCALE. This quantity is positive when the temperature is above the reference and is
negative for cold temperatures.
TEMP_RAW_X is the raw processed value from ADC output and is the fundamental quantity for temperature measurement.
TEMP_RAW_X is less than TEMP_NOM at higher temperatures. TEMP_RAW_X is more than TEMP_NOM for cooler
temperatures than reference temperature.
GAIN_ADJ is a scaling factor for power measurements based on temperature (when in internal temperature compensation
mode). In general, for higher temperatures it is lower than 16384 and higher than 16384 for lower temperatures. GAIN_ADJ is
mainly dependent on the PPMC, PPMC2 and TEMP_X register values. This parameter is automatically computed by the CE
and is used by the CE for temperature compensation.
CE
Address
Name Description
0x40 TEMP_X Deviation from Calibration temperature. LSB = 0.1
0
C.
0x54 TEMP_RAW_X
Filtered, unscaled reading from temperature sensor. This value should be
written to TEMP_NOM during meter calibration.
0x2E GAIN_ADJ
Scales all voltage and current inputs. 16384 provides unity gain. Default is
16384. If EXT_TMP = 0, GAIN_ADJ is updated by the CE.