User guide
71M6533-DB Demo Board User’s Manual   
Page: 21 of 75  `  REV 3 
1.8.2  USING THE DEMO BOARD FOR ENERGY MEASUREMENTS 
The 71M6533-DB Demo Board was designed for use with current transformers (CT). 
The  Demo  Board  may  immediately  be  used  with  current  transformers  having  2,000:1  winding  ratio  and  is 
programmed for a Kh factor of 3.2 and (see Section 1.8.4 for adjusting the Demo Board for transformers with 
different turns ratio). 
Once, voltage is applied and load current is flowing, the red LED D5 will flash each time an energy sum of 3.2 
Wh  is collected.  The  LCD display  will  show  the accumulated  energy  in  Wh  when set  to  display mode  3 
(command >M3 via the serial interface). 
Similarly, the red LED D6 will flash each time an energy sum of 3.2 VARh is collected. The LCD display will 
show the accumulated energy in VARh when set to display mode 5 (command >M5 via the serial interface). 
1.8.3  ADJUSTING THE KH FACTOR FOR THE DEMO BOARD 
The 71M6533-DB Demo Board is shipped with a pre-programmed scaling factor Kh of 3.2, i.e. 3.2Wh per pulse. 
In order to be used with a calibrated load or a meter calibration system, the board should be connected to the 
AC power source using the spade terminals on the bottom of the board. The current transformers should be 
connected to the dual-pin headers on the bottom of the board. 
The Kh  value can be  derived by reading the  values for  IMAX and  VMAX (i.e. the  RMS  current and  voltage 
values  that  correspond  to  the  250mV  maximum  input  signal  to  the  IC),  and  inserting  them  in  the  following 
equation for Kh: 
Kh = IMAX * VMAX * 66.1782 / (In_8 * WRATE * N
ACC 
* X) = 3.19902 Wh/pulse. 
The small deviation between the adjusted Kh of 3.19902 and the ideal Kh of 3.2 is covered by calibration. The 
default values used for the 71M6533-DB Demo Board are: 
WRATE:  683 
IMAX:  208 
VMAX:  600 
In_8:  1  (controlled by IA_SHUNT = 0) 
N
ACC
:   2520  
X:  6 
Explanation of factors used in the Kh calculation: 
WRATE:  The factor input by the user to determine Kh 
IMAX:  The current input  scaling  factor, i.e. the input current generating  177mVrms at the IA/IB/IC 
input pins of the 71M6533. 177mV rms is equivalent to 250mV peak. 
VMAX:  The voltage input scaling factor, i.e. the voltage generating 177mVrms at the VA/VB/VC input 
pins of the 71M6533 
In_8:  The setting for the additional ADC gain (8 or 1) determined by the CE register IA_SHUNT 
N
ACC
:   The number of samples per accumulation interval, i.e. PRE_SAMPS *SUM_CYCLES 
X:  The pulse rate control factor determined by the CE registers PULSE_SLOW and PULSE_FAST 
Almost any desired Kh factor can be selected for the Demo Board by resolving the formula for WRATE: 
  WRATE = (IMAX * VMAX * 66.1782) / (Kh * In_8 * N
ACC
 * X) 
For the Kh of 3.2Wh, the value 171 (decimal) should be entered for WRATE at location 21 (using the CLI 
command >]21=+171). 
1.8.4  ADJUSTING THE DEMO BOARDS TO DIFFERENT CURRENT TRANS-
FORMERS 
The  Demo  Board is  prepared for use  with  2000:1  current  transformers  (CTs). This  means  that  for the 
unmodified  Demo  Board,  208A  on  the primary  side  at  2000:1  ratio  result  in  104mA  on  the  secondary  side, 
causing 177mV at the 1.7 resistor pairs R24/R25, R36/R37, R56/R57 (2 x 3.4 in parallel). 