User guide
71M6533-DB Demo Board User’s Manual   
Page: 28 of 75  `  REV 3 
are 64 bits long and are accessed with )n$$ (read) and )n=hh=ll (write) in the case of accumulation variables. 
Default values are the values assigned by the Demo Code on start-up. 
All  MPU  Input Parameters  are loaded  by the  MPU at  startup and  should not  need adjustment  during meter 
calibration. 
MPU Input Parameters for Metering 
XRAM 
Word 
Address 
Default 
Value 
Name 
Description 
0x00 
433199 
ITHRSHLDA 
For each element, if WSUM_X or VARSUM_X of that element ex-
ceeds WCREEP_THR, the sample values for that element are not 
zeroed. Otherwise, the accumulators for Wh, VARh, and VAh are 
not  updated  and  the  instantaneous  value  of  IRMS  for  that 
element is zeroed. 
16
2I0SQSUM LSB
The default value is equivalent to 0.08A. Setting ITHRSHLDA to 
zero disables creep control. 
0x01 
0 
CONFIG 
Bit 0:  Sets VA calculation mode. 
0: V
RMS
*A
RMS 
1: 
22
VARW 
Bit  1:    Clears  accumulators  for Wh, VARh,  and  VAh.    This  bit 
need not be reset. 
0x02 
764569660 
PK_VTHR 
When the voltage exceeds this value, bit 5 in the MPU status 
word is set, and the MPU might choose to log a warning. Event 
logs are not implemented in Demo Code. 
16
2V0SQSUM LSB
The default value is equivalent to 20% above 240Vrms. 
0x03 
275652520 
PK_ITHR 
When the current exceeds this value, bit 6 in the MPU status 
word is set, and the MPU might choose to log a warning. Event 
logs are not implemented in Demo Code. 
16
2I0SQSUM LSB
The default value is equivalent to 20% above 30A
RMS 
. 
0x04 
0 
Y_CAL_DEG0 
RTC adjust, 100ppb. Read only at reset in demo code. 
0x05 
0 
Y_CAL_DEG1 
RTC adjust, linear by temperature, 10ppb*ΔT, in 0.1˚C. Provided 
for optional code. 
0x06 
0 
Y_CAL_DEG2 
RTC  adjust,  squared  by  temperature,  1ppb*ΔT
2
,  in  0.1˚C. 
Provided for optional code. 
0x07 
0 
PULSEW_SRC 
This address contains a number that points to the selected pulse 
source for the Wh output. Selectable pulse sources are listed in 
Table 1-5.  
0x08 
4 
PULSER_SRC 
This address contains a number that points to the selected pulse 
source for the VARh output. Selectable pulse sources are listed 
in Table 1-5. 
0x09 
6000 
VMAX 
The nominal external  RMS voltage that corresponds  to 250mV 
peak  at  the  ADC  input.  The  meter  uses  this  value  to  convert 
internal quantities to external. LSB=0.1V 
0x0A 
2080 
IMAX 
The  nominal external  RMS  current  that corresponds to  250mV 
peak at the ADC input for channel A. The meter uses this value 
to convert internal quantities to external. LSB=0.1A 