MPU STATUS WORD 
The MPU maintains the status of certain meter and I/O related variables in the Status Word. The Status Word is 
located at address 0x21. The bit assignments are listed in Table 1-7. 
Status 
Word Bit 
Name 
DESCRIPTION 
0 
CREEP 
Indicates that all elements are in creep mode. The CE’s pulse variables 
will be “jammed” with a constant value on every accumulation interval to 
prevent spurious pulses. Note that creep mode therefore halts pulsing 
even when the CE’s pulse mode is “internal”. 
1 
MINVC 
Element C has a voltage below VThrshld.  This forces that element into 
creep mode. 
2 
PB_PRESS 
A push button press was recorded at the most recent reset or wake from 
a battery mode. 
3 
SPURIOUS 
An unexpected interrupt was detected. 
4 
MINVB 
Element B has a voltage below VThrshld. This forces that element into 
creep mode. 
5 
MAXVA 
Element A has a voltage above VThrshldP. 
6 
MAXVB 
Element B has a voltage above VThrshldP. 
7 
MAXVC 
Element C has a voltage above VThrshldP. 
8 
MINVA 
Element A has a voltage below VThrshld. This forces that element into 
creep mode. It also forces the frequency and main edge count to zero. 
9 
WD_DETECT 
The  most  recent  reset  was  a watchdog  reset.    This  usually  indicates  a 
software error. 
10 
MAXIN 
The neutral current is over INThrshld.  In a real meter this could indicate 
faulty distribution or tampering. 
11 
MAXIA 
The current of element A is over IThrshld. In a real meter this could 
indicate overload. 
12 
MAXIB 
The current of element B is over IThrshld. In a real meter this could 
indicate overload. 
13 
MAXIC 
The current of element C is over IThrshld. In a real meter this could 
indicate overload. 
14 
MINT 
The temperature is below the minimum, -40C, established in option_gbl.h. 
This is not very accurate in the demo code, because the calibration 
temperature is usually poorly controlled, and the default temp_nom is 
usually many degrees off. –40C is the minimum recommended operating 
temperature of the chip. 
15 
MAXT 
The temperature is above the maximum, 85C, established in option_gbl.h. 
This is not very accurate in the demo code, because the calibration 
temperature is usually poorly controlled, and the default temp_nom is 
usually many degrees off. 85C is the maximum recommended operating 
temperature of the chip. 
16 
BATTERY_BAD 
Just after midnight, the demo code sets this bit if VBat < VBatMin.  The 
read is infrequent to reduce battery loading to very low values.  When the 
battery voltage is being displayed, the read occurs every second, for up to 
20 seconds. 
17 
CLOCK_TAMPER 
Clock set to a new value more than two hours from the previous value. 
18 
CAL_BAD 
Set after reset when the read of the calibration data has a bad longitudinal 
redundancy check or read failure. 
19 
CLOCK_UNSET 
Set when the clock’s current reading is A) More than a year after the 
previously saved reading, or B) Earlier than the previously saved reading, 
or C) There is no previously saved reading. 