lcd_idx
Selects LCD’s cur-
rent display.
0: Meter identification. (“#”)
1: Display variation from calibra-
tion temperature, 0.1C
2: Display mains Hz, 0.1 Hz
3: mWh, total
4: mWh total exported.
5: mVARh, total.
6: mVARh, total exported.
7:mVAh, total
8: Operating hours.
9: Time of day
10: Calendar date
11: Power factor, total
12: Angle between phase 0 & 1
13: Main edge count, last accu-
mulation.
14: KW, instantaneous total
15: V, instantaneous max of all
phases.
16: A, total
17: V, Battery (“VB”)
18: Seconds, bad power (“BPS”)
19: Seconds, tamper (- = tamper
in progress) (“TS”)
20: LCD Test
Scrolling not standard for these:
111: PF, phase 0
112: Angle, phase 0 & 1
114: KW, phase 0
115: V, phase 0
116: A, phase 0
211: PF, phase 1
212: Angle, phase 0 & 2
214: KW, phase 1
215: V, phase 1
216: A, phase 1
311: PF, phase 2
312: Angle, phase 2.0
314: KW, phase 2
315: V, phase 2
316: A, phase 2
416: A, neutral (measured)
3 )19 signed 16
lcd_bit
Defines sequence
of LCD displays.
The value is a bit mask that de-
scribes a scrolling display se-
quence. Each set bit permits a
display with an lcd_idx value
from 0..31. Each is displayed for
7 seconds. Ordered by increas-
ing bit number. If value is zero,
display does not change.
0 )1A unsigned 32
mfr_id
6
Manufacturer’s ID
text string of the
meter
3 ASCII bytes, in MSB of 32-bit
number. Least significant byte
should be zero. For AMR
demonstrations, sent as the
manufacturer’s ID of the meter.
“TSC”,
0x54534300
)1B unsigned 32