Datasheet

71M6541D/F/G and 71M6542F/G Data Sheet
Rev 4 131
5.3.8 CE Transfer Variables
When the MPU receives the XFER_BUSY interrupt, it knows that fresh data is available in the transfer
variables. CE transfer variables are modified during the CE code pass that ends with an XFER_BUSY
interrupt. They remain constant throughout each accumulation interval. In this data sheet, the names of
CE transfer variables always end with _X”. The transfer variables can be categorized as:
Fundamental energy measurement variables
Instantaneous (RMS) values
Other measurement parameters
5.3.8.1 Fundamental Energy Measurement Variables
Table 85 and Table 86 describe each transfer variable for fundamental energy measurement. All
variables are signed 32-bit integers. Accumulated variables such as WSUM are internally scaled so they
have at least 2x margin before overflow when the integration time is one second. Additionally, the hardware
does not permit output values to fold back upon overflow.
Table 85: CE Transfer Variables (with Local Sensors)
CE
Address
Name Description Configuration
0x84
WSUM_X
The signed sum: W0SUM_X+W1SUM_X. Not used
for EQU[2:0] = 0 (I/O RAM 0x2106[7:5]) and
EQU[2:0] = 1.
Figure 35 (page 93)
Figure 37 (page 95)
0x85
W0SUM_X
The sum of Wh samples from each wattmeter
element.
LSB = 9.4045*10
-13
* VMAX * IMAX Wh.
For ce41a04: LSB = 6.6952*10
-13
* VMAX * IMAX
Wh.
0x86
W1SUM_X
0x88
VARSUM_X
The signed sum: VAR0SUM_X+VAR1SUM_X. Not
used for
EQU[2:0]
= 0 and
EQU[2:0]
= 1.
0x89
VAR0SUM_X
The sum of VARh samples from each wattmeter
element.
LSB = 9.4045*10
-13
* VMAX * IMAX VARh.
For ce41a04, LSB = 6.6952*10
-13
* VMAX * IMAX
VARh.
0x8A
VAR1SUM_X
Note:
71M6542 only.
Table 86: CE Transfer Variables (with Remote Sensor)
CE
Address
Name Description Configuration
0x84
WSUM_X
The signed sum: W0SUM_X+W1SUM_X. Not used
for EQU[2:0] = 0 (I/O RAM 0x2106[7:5]) and
EQU[2:0] = 1.
Figure 36 (page 94)
Figure 38 (page 96)
0x85
W0SUM_X
The sum of Wh samples from each wattmeter
element.
LSB = 1.55124*10
-12
* VMAX* IMAX Wh.
0x86
W1SUM_X
0x88
VARSUM_X
The signed sum: VAR0SUM_X+VAR1SUM_X. Not
used for EQU[2:0] = 0 and EQU[2:0] = 1.
0x89
VAR0SUM_X
The sum of VARh samples from each wattmeter
element.
LSB = 1.55124*10
-12
*VMAX* IMAX VARh.
0x8A
VAR1SUM_X
Note:
71M6542 only.