Datasheet

71M6541D/F/G and 71M6542F/G Data Sheet
6 Rev 4
Tables
Table 1. Required CE Code and Settings for Local Sensors ...................................................................... 15
Table 2. Required CE Code and Settings for 71M6x01 Isolated Sensor ................................................... 16
Table 3: ADC Input Configuration .............................................................................................................. 17
Table 4: Multiplexer and ADC Configuration Bits ...................................................................................... 19
Table 5. RCMD[4:0] Bits ............................................................................................................................. 23
Table 6: Remote Interface Read Commands ............................................................................................ 23
Table 7: I/O RAM Control Bits for Isolated Sensor .................................................................................... 23
Table 8: Inputs Selected in Multiplexer Cycles ........................................................................................... 25
Table 9: CKMPU Clock Frequencies .......................................................................................................... 31
Table 10: Memory Map ............................................................................................................................... 32
Table 11: Internal Data Memory Map ......................................................................................................... 33
Table 12: Special Function Register Map ................................................................................................... 33
Table 13: Generic 80515 SFRs - Location and Reset Values .................................................................... 34
Table 14: PSW Bit Functions (SFR 0xD0) ..................................................................................................... 35
Table 15: Port Registers (SEGDIO0-15) ..................................................................................................... 36
Table 16: Stretch Memory Cycle Width ...................................................................................................... 36
Table 17: Baud Rate Generation ................................................................................................................ 37
Table 18: UART Modes ............................................................................................................................... 37
Table 19: The S0CON (UART0) Register (SFR 0x98) ................................................................................. 38
Table 20: The S1CON (UART1) Register (SFR 0x9B) ................................................................................ 39
Table 21: PCON Register Bit Description (SFR 0x87) ............................................................................... 39
Table 22: Timers/Counters Mode Description ............................................................................................ 40
Table 23: Allowed Timer/Counter Mode Combinations .............................................................................. 40
Table 24: TMOD Register Bit Description (SFR 0x89) ................................................................................ 40
Table 25: The TCON Register Bit Functions (SFR 0x88) ............................................................................ 41
Table 26: The IEN0 Bit Functions (SFR 0xA8) ............................................................................................ 42
Table 27: The IEN1 Bit Functions (SFR 0xB8) ............................................................................................ 42
Table 28: The IEN2 Bit Functions (SFR 0x9A) ............................................................................................ 42
Table 29: TCON Bit Functions (SFR 0x88) ................................................................................................. 42
Table 30: The T2CON Bit Functions (SFR 0xC8) ....................................................................................... 43
Table 31: The IRCON Bit Functions (SFR 0xC0) ........................................................................................ 43
Table 32: External MPU Interrupts .............................................................................................................. 44
Table 33: Interrupt Enable and Flag Bits ................................................................................................... 45
Table 34: Interrupt Priority Level Groups .................................................................................................... 45
Table 35: Interrupt Priority Levels ............................................................................................................... 45
Table 36: Interrupt Priority Registers (IP0 and IP1) .................................................................................... 46
Table 37: Interrupt Polling Sequence .......................................................................................................... 46
Table 38: Interrupt Vectors .......................................................................................................................... 46
Table 39: Flash Memory Access ................................................................................................................. 48
Table 40: Flash Security ............................................................................................................................. 49
Table 41: Clock System Summary .............................................................................................................. 51
Table 42: RTC Control Registers ................................................................................................................ 52
Table 43: I/O RAM Registers for RTC Temperature Compensation .......................................................... 53
Table 44: NV RAM Temperature Table Structure ....................................................................................... 54
Table 45: I/O RAM Registers for RTC Interrupts ........................................................................................ 55
Table 46: I/O RAM Registers for Temperature and Battery Measurement ................................................ 56
Table 47: Selectable Resources using the DIO_Rn[2:0] Bits ..................................................................... 60
Table 48: Data/Direction Registers for SEGDIO0 to SEGDIO14 (71M6541D/F/G) ................................... 61
Table 49: Data/Direction Registers for SEGDIO19 to SEGDIO27 (71M6541D/F/G) ................................. 62
Table 50: Data/Direction Registers for SEGDIO36-39 to SEGDIO44-45 (71M6541D/F/G) ....................... 62
Table 51: Data/Direction Registers for SEGDIO51 and SEGDIO55 (71M6541D/F/G) .............................. 62
Table 52: Data/Direction Registers for SEGDIO0 to SEGDIO15 (71M6542F/G) ....................................... 63