User Manual

UG_1x22_053 73M1822/73M1922 Control Module User Guide
Rev. 1.0 19
5.2.10 M1X22_OI_DETECT
This event is generated on detection of an over current line condition.
Parameters
Data Type Name Description
unsigned int
event_id
M1X22_OI_DETECT
.
unsigned int
channel_id
Channel ID.
unsigned int
event_cnt
Number of events that remain in the queue.
unsigned int
event_data1
N/A.
unsigned int
event_data2
N/A.
unsigned int
event_data3
N/A.
unsigned int
event_data4
N/A.
5.2.11 M1X22_LINE_STATE
This event is generated when the line state analysis process detects a change in the state of the line.
The line state analysis process will monitor (under user control) the line current and/or voltage in both On
and off hook states. This event indicates that either the user has requested the current line state or one
of the programmable threshold states has become active or non active.
Parameters
Data Type Name Description
unsigned int
event_id
M1X22_LINE_STATE
.
unsigned int
channel_id
Channel ID.
unsigned int
event_cnt
Number of events that remain in the queue.
unsigned int event_data1
M1X22_ON_HOOK,
M1X22_OFF_HOOK
.
unsigned int event_data2
M1X22_VOLTAGE,
M1X22_CURRENT
.
unsigned int
event_data3
IET row number.
unsigned int
event_data4
Event identifier.
5.2.12 M1X22_DIAL_COMPLETE
This event is generated when a pulse dial session is completed successfully.
Parameters
Data Type Name Description
unsigned int
event_id
M1X22_DIAL_COMPLETE
.
unsigned int
channel_id
Channel ID.
unsigned int
event_cnt
Number of events that remain in the queue.
unsigned int
event_data1
N/A.
unsigned int
event_data2
N/A.
unsigned int
event_data3
N/A.
unsigned int
event_data4
N/A.