User Manual

73M1822/73M1922 Control Module User Guide UG_1x22_053
56 Rev. 1.0
6.9 Miscellaneous
6.9.1 M1X22_THRESHOLD_OVERRIDE
Description
Various modem channel parameters are conveniently grouped and predefined in the country parameter
setting as specified in Section 7.2. These parameters are programmed during channel initialization ioctl
(M1X22_CH_INIT). However, these parameters can be overridden at runtime to fine tune to the desired
threshold for the specific installation using this M1X22_THRESHOLD_OVERRIDE IOCTL.
Note: This IOCTL must be invoked after M1X22_CH_INIT to prevent the parameter from over written by
M1X22_CH_INIT.
#define M1X22_THRESHOLD_OVERRIDE _IOWR(0xA4,0xB3,unsigned int)
Prototype
int ioctl (
int chan_fd,
int M1X22_THRESHOLD_OVERRIDE,
unsigned long param );
Parameters
Data Type Name Description
int
chan_fd
Channel descriptor.
int
M1X22_THRESHOLD_OVERRIDE
I/O control identifier for this operation.
unsigned long
param
Pointer to the M1X22_THRESH_OVERRIDE_t
structure.
Return Values
Data Type Description
int
-EFAULT Failed to perform threshold override.
0 – Successful.