3.2.2 Initial Line State Configuration
The default condition of the device is to be on hook after reset and startup.
The registers used in this procedure are:
0x05 ENGPIO7 ENGPIO6 ENGPIO5 ENGPIO4 ENAPOL ENDET ENSYNL ENRGDT
Write X X X X 1 X 1 X
0x12
OFH
ENDC
ENAC
ENSHL
ENLVD
ENFEL
ENDT
ENNOM
Write 0 0 0 0 0 1 0 0
0x13 DCIV1 DCIV0 ILM RSVD PLDM OVDTH IDISPD1 IDISP0
Write VAL1[1:0] 0 0 0 0 0 0
0x14
TXBST
DAA1
DAA0
Res
RXBST
RLPNH
RXG1
RXG0
Write X X X 0 X X X X
0x15 RSVD DISNTR Res CIDM THEN ENUVD ENOVD ENOID
Write 0 0 0 0 1 0 0 0
0x16
TXEN
RXEN
RLPNEN
ATEN
FSCTR3
FSCTR2
FSCTR1
FSCTR0
Write
1
1
0
1
VAL3[3:0]
0x17
APWS Res Res ACZ1 ACZ0 Res Res Res
Write 0 0 0 VAL2[1:0] 0 0 0
The temporary variables defined in this procedure are:
VAL1 = Set the DCIV bits to the desired DC current voltage characteristic as defined in the Data Sheet.
VAL2 = System appropriate value for ACZ[1:0].
VAL3 = System appropriate value for FSCTR[3:0].
Begin
1. Set ENAPOL =1 and ENSYNL = 1, to allow automatic polling of line side registers (write RG05 =
xxxx_1x1x).
2. Set ENFEL = 1, OFH = ENDC = ENAC = ENSHL = ENVLD = ENDT = ENNOM = 0 (Write RG12 =
0x40).
3. Set ILM = RSVD = PLDM = OVDTH = IDISPD = Res = 0, DCIV = VAL1 (Write RG13 =
Val1[1:0]00_0000).
4. Write RG14 = xxx0_xxxx
5. Set THEN = 1, set ENOLD = DISNTR = CHPSEN = CIDM = ENUVD = ENOVD = ENOID = 0 (Write
RG15 = 0000_1000)
6. Set TXEN = RXEN = ATEN = 1, RLPNEN = 0 and FSCTR[3:0] =VAL3[3:0] (Write RG16 =
1101_VAL3[3:0]).
7. Set RG17[4:3] = VAL2 (write RG17 = 0x000_VAL2_000).
End
After this point the host may selectively enable other on hook operations such as ring detection or CID