3.2 Line-Side Device (73M1916) Configuration
The Line-side device setup includes the following procedures:
1. Barrier Synchronization Recovery
2. Receiver DC Offset Calibration
3. Initial Line State Configuration
3.2.1 Barrier Synchronization Recovery
Before the Line-side device can be initialized, the barrier must be in sync and error free. The barrier is
designed to power up the line-side device and come into sync automatically upon PLL lock. The user
should check that the device indicates barrier sync before proceeding with line-side initialization.
The following registers control the Barrier Sync procedure.
0x03 GPIO7 GPIO6 GPIO5 PCLKDT RGMON DET SYNL RGDT
Write X X X X X X ? X
0x05 ENGPIO7 ENGPIO6 ENGPIO5 ENPCLKDT ENAPOL ENDET ENSYNL ENRGDT
Write X X X X X X 1 X
0x0D
LOKDET
SLHS
Res
Res
RSTLSBI
Res
Res
Res
Read ? ? X X 1/0 X X X
0x0F
ENFEH
PWDN
SLEEP
Res
Res
Res
Res
Res
Write X X 1/0 X X X X X
0x23
PCMEN
MASTER
PCODE3
PCODE2
PCODE1
PCODE0
LIN
LAW
Write X 1/0 0 0 0 0 X X