Owner's manual

UG_1x66B_016 73M1866B/73M1966B Implementer’s Guide
Rev. 1.3 17
4 On-Hook Procedures
The on-hook procedures described in this section include:
CID Mode
Off-Hook Request
Ring Detection and Line Voltage Reversal
Line-in-use and Loss of Battery Feed
4.1 CID Mode
It is possible (while on hook) to allow the RGP/RGN input, which is AC coupled to the line through high
voltage capacitors, to be transmitted on the PCM bus. This allows the host to listen for Caller ID
information without going off hook.
The registers used in this procedure are:
0x14
TXBST
DAA1
DAA0
Res
RXBST
RLPNH
RXG1
RXG0
Write X X X X 1 X X X
0x15 ENOLD DISNTR Res CIDM THEN ENUVD ENOVD ENOID
Write X X 1 1 X X X X
Begin
1. Set RXBST = 1 (Write RG14 = xxxx1xxx).
2. Set CHPSEN = 1, CIDM = 1 (write RG15 = xx11_xxxx).
End
CID Mode
RXBST =1
CHPSEN =1
CIDM =1
End