73M1903 Data Sheet DS_1903_032
32 Rev. 2.1
Parameter Test Condition Min Nom Max Units
TXAP/N Output
Impedance
Differentially
(TXDIS=1)
TXDIS=1
Measure impedance differentially
between TXAP and TXAN.
160 k
TXAP/N Common
Output Offset
(TXDIS=1)
TXDIS=1
Short TXAP and TXAN. Measure the
voltage respect to Vbg.
-20 0 20 mV