Datasheet
73M1866B/73M1966B Data Sheet DS_1x66B_001
26 Rev. 1.6
3.10 Transmit Hybrid Cancellation
Table 21 lists the transmit hybrid cancellation characteristics. Unless stated otherwise, test conditions
are: ACZ[3:0]=0000 (600 Ω termination), THEN=1, ATEN=1, DAA[1:0]=01, TXBST=0. TXM is externally
fed back into the 73M1916 to effect cancellation of transmit signal.
Table 21: Transmit Hybrid Cancellation Characteristics
Parameter
Test Condition
Min
Nom
Max
Units
Transmit hybrid cancellation Measure in
73M1906B
– 20 – dB
Offset voltage 50% 1’s density – 0 25 mV
AC swing 1 kHz sinusoid 1.00 1.05 1.10 Vpk
Idle noise 300 Hz – 4 kHz – -80 – dBm
3.11 Receive Notch Filter
Table 22 lists the receive notch filter characteristics. All measurements taken with RLPNEN=1, TXEN=0,
RXG=00, ATEN=1. RXP is driven with 1 Vpk signal.
Table 22: Receive Notch Filter
Parameter Test Condition Min Nom Max Unit
Magnitude response
RLPNH=0 (12 kHz Notch)
300 Hz
–
0.0
–
dB
1 kHz
–
+0.03
–
dB
3 kHz
–
+0.04
–
dB
12 kHz -30 -50
–
dB
Passband Ripple (0.3 kHz – 3.4 kHz)
–
+/- 0.15
–
dB
Delay
–
28.8
–
μs
300 Hz
–
28.93
–
μs
1 kHz
–
30.25
–
μs
3 kHz
–
41.62
–
μs
12 kHz
–
9.95
–
μs
Magnitude response
RLPNH=1 (16 kHz Notch)
300 Hz
–
0.0
–
dB
1 kHz
–
+0.04
–
dB
3 kHz
–
+0.11
–
dB
16 kHz
-30
-50
–
dB
Passband Ripple (0.3 kHz – 3.4 kHz)
–
+/- 0.15
–
dB
Delay
–
30.53
–
μs
300 Hz
–
30.66
–
μs
1 kHz
–
31.93
–
μs
3 kHz
–
42.26
–
μs
16 kHz
–
4.74 – μs