Datasheet

78M6610+PSU Data Sheet
Relay
Command
Line
Voltage
T
ON
_
DELAY
De
-
Energized
Energized
De
-Energized
T
OFF
_DELAY
Figure 2-10: Relay Control
Table 2-1: Relay Configuration Register and Sequence Delay Register
Function
Register
Default
Value
Comments
Name Address
TON_Delay
RelayOnDelay 0x6b 0
Line Relay Activation Time
Delay
TOFF_Delay
RelayOffDelay 0x6c 0
Line Relay De-Activation Time
Delay
Rev 3 19