Datasheet

78M6610+PSU Data Sheet
3.5 Relay Configuration
The registers in Table 3-6 are used to configure the relay operations.
Table 3-6: Relay Configuration Registers
Address
Register Format
Flash
Saved
Description
Default
(Decimal)
0x12F RelayOnMin UINT24
Y Minimum Voltage to Keep Relay ON (LSB
weight determined by Vscale)
85,000
0x132
RelayOnMax
UINT24
Y Maximum Voltage to Keep Relay ON (LSB
weight determined by Vscale)
255,000
0x135
RelayOnTime
UINT24
Y Hold ON Time (Samples) If Min/Max Not Met 4
0x138 RelayOffMin UINT24
Y Minimum Voltage to Keep Relay OFF (LSB
weight determined by Vscale)
90,000
0x13B RelayOffMax
UINT24
Y Maximum Voltage to Keep Relay OFF (LSB
weight determined by Vscale)
250,000
0x13E RelayOffTime
UINT24
Y Hold OFF Time (Samples) If Min/Max Met 4
0x141
RelayOnDelay
UINT24
Y Relay Closure Time (ms) 0
0x144 RelayOffDelay
UINT24
Y Relay Opening Time (ms) 0
Rev 3 29