3.8.6 Calibration Command (0xCAxxxx)
Use this command to start the calibration process for the selected inputs. It is assumed that appropriate
input signals are applied before starting calibration. When the calibration process completes, bits [23:16]
are cleared along with bits associated with channels that calibrated successfully. Any channels that failed
will have their corresponding bit left set.
Table 3-21. Calibration Command Bits
Bit(s)
Value
Description
23:16 0xCA “Calibrate” Command
15:14
0
Not used (set to 0)
13 XYR Calibrate X+Y or R Compensation Coefficient (instead of gain)
12 V Calibrate Voltage (gain or offset)
11 I Calibrate Current (gain or offset)
10 T Calibrate Chip Temperature
9 O Calibrate Offset (instead of gain) for Current or Voltage
8
XT
Calibrate External Temperature Gain
7:0 See General Settings (0x00xxxx)