78M6610+PSU Data Sheet
4.1.2 Auto-Reported Data
By default, the 78M6610+PSU automatically reports a set of data at the completion of each accumulation
interval. This mode is used in systems where the host will not have to poll the 78M6610+PSU for data but
it receives automatically data updated at the accumulation interval rate. Table 4-3
shows the default auto-
reported data format.
Table 4-3: Default Measurements
Parameter/Register
Number of
Bytes
Description
Packet Header 1 Start of Data Packet
Packet Length 1 Number of Bytes in the Packet
Vrms 3 RMS Voltage (address 0x1B)
Irms 3 RMS Current (address 0x1E)
Watt 3 Active Power (address 0x21)
PAverage 3 Active Power (30s average) (address 0x24)
PF 3 Power Factor (address 0x27)
Frequency 3 Line Frequency (address 0x2A)
DevAddr 3 High Order Device ID and Address Bits (address 0x2D)
Alarms 3 Alarms and Status (address 0x30)
The content of the auto-reported data packet is configurable by the user. Refer to the relevant application
note describing the auto-report packet configuration procedure.
Rev 3 47