Instruction Manual

DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver
190 of 344
Register Name:
SU.MACFCR
Register Description:
MAC Flow Control Register
Register Address:
001Ch (indirect)
001Ch:
Bit # 31 30 29 28 27 26 25 24
Name PT15 PT14 PT13 PT12 PT11 PT10 PT09 PT08
Default 0 0 0 0 0 0 0 0
001Dh:
Bit # 23 22 21 20 19 18 17 16
Name PT07 PT06 PT05 PT04 PT03 PT02 PT01 PT00
Default 0 1 0 1 0 0 0 0
001Eh:
Bit # 15 14 13 12 11 10 09 08
Name Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved
Default 0 0 0 0 0 0 0 0
001Fh:
Bit # 07 06 05 04 03 02 01 00
Name Reserved Reserve
d
Reserved Reserved Reserved Reserved FCE FCB
Default 0 0 0 0 0 0 1 0
Bits 16 - 31: Pause Time (PT[00:15]) These bits are used for the Pause Time Field in transmitted Pause Frames.
This value is the number of time slots the remote node should wait prior to transmission.
Bit 1: Flow Control Enable (FCE) When set to 1, the MAC automatically detects pause frames and will disable
the transmitter for the requested pause time.
Bit 0: Flow Control Busy (FCB) The host can set this bit to 1 in order to initiate transmission of a pause frame.
During transmission of a pause frame, this bit remains set. The DS33R11 will clear this bit when transmission of
the pause frame has been completed. The user should read this bit and ensure that this bit is equal to zero prior to