Instruction Manual

DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver
296 of 344
Register Name:
TR.BIC
Register Description:
BERT Interface Control Register
Register Address:
EAh
Bit # 7 6 5 4 3 2 1 0
Name — RFUS TBAT TFUS BERTDIR BERTEN
Default 0 0 0 0 0 0 0 0
Bit 6: Receive Framed/Unframed Select (RFUS)
0 = BERT is not sent data from the F-bit position (framed)
1 = BERT is sent data from the F-bit position (unframed)
Bit 4: Transmit Byte-Align Toggle (TBAT). A 0-to-1 transition forces the BERT to byte align its pattern with the
transmit formatter. This bit must be transitioned in order to byte align the Daly pattern.
Bit 3: Transmit Framed/Unframed Select (TFUS)
0 = BERT does not source data into the F-bit position (framed)
1 = BERT does source data into the F-bit position (unframed)
Bit 1: BERT Direction (BERTDIR)
0 = network
BERT transmits toward the network (TTIP and TRING) and receives from the network (RTIP and RRING). The
BERT pattern can be looped back to the receiver internally by using the framer loopback function.
1 = system
BERT transmits toward the system backplane (RSERO) and receives from the system backplane (TSERI).
Bit 0: BERT Enable (BERTEN)
0 = BERT disabled