4
Evaluates: MAX14588MAX14588 Evaluation Kit
www.maximintegrated.com
Switch Control
TheEVkitfeaturestwojumpers(JU6,JU8)toenableor
disable the switch. See Table 4 for jumper settings.
Reverse-Current Block Enable
UsejumperJU9toenableordisablethereverse-current
flow protection. The reverse-current block is enabled
whenRIENislogic-high.SeeTable6forjumpersettings.
Current-Limit Type Select
TheEVkitfeaturesjumpersJU12,JU14,JU15toselect
differentcurrent-limittypeandsampledtime.SeeTable7
for jumper settings.
Output Load Capacitor
UsejumperJU13toconnectoutputto330µFcapacitor.
SeeTable9forjumpersettings.
*Default position.
*Default position.
*Default position.
*Default position.
JUMPER
SHUNT
POSITION
DESCRIPTION
JU6
1-2
HVEN connected to IN
through100kΩ.
2-3* HVEN connected to ground.
JU8
Installed*
ENconnectedtoVBUS.
Not
installed
EN connected to ground
through100kΩ.
JUMPER
SHUNT
POSITION
DESCRIPTION
JU13
Installed
OUTconnectedtoC7andC8.
Not
installed*
OUTnotconnectedto
C7andC8.
JUMPER
SHUNT
POSITION
DESCRIPTION
JU9
Installed*
RIENconnectedtoVBUS.
Not
installed
RIENconnectedtoground
through100kΩ.
JUMPER
SHUNT
POSITION
DESCRIPTION
JU12
1-2*
CLTS_MODEhigh.CLTS1
andCLTS2aresampled
continuously.
2-3
CLTS_MODElow.CLTS1and
CLTS2aresampledonlywhen
VIN - VOUT<0.6V.
JU14
1-2*
CLTS1high.
2-3 CLTS1low.
JU15
1-2
CLTS2high.
2-3* CLTS2low.
HVEN EN SWITCH STATUS
0 0 On
0 1 On
1 0 Off
1 1 On
CLTS2 CLTS1 CURRENT-LIMIT TYPE
0 0 Latchoff
0 1 Autoretry
1 0 Continuous
1 1 Continuous
Table 4. Switch Control (JU6, JU8)
Table 9. Output Load Capacitor (JU13)
Table 6. Reverse-Current Block Enable
(JU9)
Table 7. Current-Limit Type Select
(JU12, JU14, JU15)
Table 5. Enable Inputs
Table 8. Logic Inputs