Output Preemphasis (JU2, JU3)
The host and device can be evaluated with or without
output preemphasis. Configure JU2 to enable/disable the
host output (HAP, HAM) preemphasis and JU3 to enable/
disable the device output (DBM, DBP) preemphasis (see
Tables 4 and 5).
Out-of-Band (OOB) Mode Selection (JU8)
The application circuit provides full OOB signal support
through high-speed OOB-detection circuitry. The SATA
range used can be selected through configuration of jump-
er JU8 (see Table 6). When the MODE pin is set to GND,
the SATA version 3.0 range is used. When the MODE pin
is set to +3.3V, the SATA version 2.6 range is used.
Characterization Circuit (U2)
The characterization circuit is provided as a separate test
circuit for eye diagram evaluation of the device. This cir-
cuit provides differential SMA inputs and outputs with 50Ω
controlled-impedance traces. Channel B is not utilized in
this section of the EV kit, but provides the same perfor-
mance as channel A.
Input Supply (VCC)
The characterization circuit is powered by an external
+3.3V power supply connected between the VCC and
GND PCB pads.
Device Enable (JU5)
The characterization circuit is enabled/disabled by con-
figuring jumper JU5 (see Table 7). When disabled, the
device buffers are powered down and the part is placed
in a low-power mode.
*Default configuration.
*Default configuration.
*Default configuration.
*Default configuration.
SHUNT
POSITION
PB PIN (U1) DESCRIPTION
1-2
Connected to
+3.3V
Host output preemphasis
enabled
2-3*
Connected to
GND
Host output preemphasis
disabled
Not installed Not connected
SHUNT
POSITION
PA PIN (U1) DESCRIPTION
1-2
Connected to
+3.3V
Device output
preemphasis enabled
2-3*
Connected to
GND
Device output
preemphasis disabled
Not installed Not connected
SHUNT
POSITION
MODE PIN
(U1)
DESCRIPTION
1-2
Connected to
+3.3V
SATA version 2.6 range
is used
2-3*
Connected to
GND
SATA version 3.0 range
is used
SHUNT
POSITION
EN PIN (U2) DESCRIPTION
1-2*
Connected to
+3.3V
Buffers enabled
for normal operation
2-3
Connected to
GND
Buffers disabled and the
device is in low-power
standby mode
Table 4. Jumper JU2 Function (U1 PB)
Table 5. Jumper JU3 Function (U1 PA)
Table 6. Jumper JU8 Function (U1 MODE)