Datasheet
MAX17113 Evaluation Kit
Evaluates: MAX17113
_______________________________________________________________________________________ 5
Enable-Control Inputs (EN1, EN2)
The MAX17113 EV kit features jumpers JU3 and JU4 to
control the two switching regulators and the two charge-
pump regulators’ enable inputs. Jumper JU3 controls the
step-down and negative charge-pump regulator enable
input (EN1). Jumper JU4 controls the step-up and posi-
tive charge-pump regulator enable input (EN2). EN2 is
inactive when EN1 is low. See Table 4 for jumper JU3
and JU4 functions.
High-Voltage Switch-Control Input (CTL)
Jumper JU5 configures the setting to control the high-
voltage switch-control pin (CTL) of the MAX17113 IC.
The switch between the SRC and GON pins and the
switch between the GON and DRN pins can also be con-
trolled by an external logic controller connected to the
CTL pad. See Table 5 for switch states and refer to the
High-Voltage Switch Control section in the MAX17113 IC
data sheet for further information about the high-voltage
switches connected to the GON pin.
VGON Discharge Path
The MAX17113 EV kit features a method to configure the
VGON discharge path using resistor R15 and jumper
JU6. When CTL is low, GON is connected to DRN, allow-
ing VGON to discharge through resistor R15. JU6 selects
the discharge path by connecting R15 to AVDD (through
diode D6) or to PGND. Table 6 lists the selectable JU6
jumper options.
Positive Charge-Pump Stage Selection
Jumper JU7 is provided to select between a positive
dual-stage charge pump and a positive single-stage
charge pump. Table 7 lists the selectable JU7 jumper
options.
High-Voltage Switch-Control Block
Output (GON)
Jumper JU8 is provided to connect or disconnect a
bypass capacitor to the high-voltage switch-control
block output GON terminal. Table 8 lists the selectable
JU8 jumper options.
Table 5. Jumper JU5 Functions
Table 7. Jumper JU7 Functions
Table 8. Jumper JU8 Functions
Table 6. Jumper JU6 Functions
*Default position.
*Default position.
*Default position.
*Default position.
SHUNT
POSITION
CTL PIN
MAX17113 HIGH-
VOLTAGE SWITCH
CONFIGURATION
Installed* Connected to VL GON connected to SRC
Not installed
Connected to
AGND (through
resistor R14)
GON connected to DRN
Not Installed
(external
logic
controller
connected
to CTL pad)
External logic
controller
GON pin connected to
SRC pin
(CTL driven high)
GON pin connected to
DRN pin
(CTL driven low)
SHUNT POSITION POSITIVE CHARGE PUMP
1-2 Single-stage charge pump
2-3* Dual-stage charge pump
SHUNT POSITION C21 BYPASS CAPACITOR
Installed Enabled
Not installed* Disabled
SHUNT
POSITION
DRN PIN
VGON
DISCHARGED
TOWARDS
1-2*
Connected to AVDD
(through resistor R15 and
diode D6)
AVDD
2-3
Connected to PGND
(through resistor R15 )
PGND