Datasheet

General Description
The MAX3054/MAX3055/MAX3056 are interfaces
between the protocol controller and the physical wires
of the bus lines in a controller area network (CAN). The
devices provide differential transmit capability and switch
to single-mode if certain fault conditions occur. The
MAX3054/MAX3055/MAX3056 guarantee full wakeup
capability during failure modes.
The extended fault-protected voltage range of CANH and
CANL bus lines of ±80V. Current-limiting and thermalpro-
tection circuits protect the transmitter output stage against
overcurrent faults to prevent destruction of the transmitter
output stage. The CANH and CANL lines are also protect-
ed against electrical transients that may occur in rugged
environments.
The transceiver provides three low-power modes that
can be entered and exited through pins STB and EN. An
output INH pin can be used for deactivation of an external
voltage regulator.
The MAX3054/MAX3055/MAX3056 are designed to provide
optimal operation for a specified data rate. The MAX3054 is
ideal for high data rates of 250kbps. The MAX3055 is used
for data rates of 125kbps and the MAX3056 is designed for
40kbps applications. For 40kbps and 125kbps versions, a
built-in slope-control feature allows the use of unshielded
cables, and receiver input filters guarantee high noise immunity.
Applications
Industrial HVAC
Features
±80V Fault Protection
Low RFI/Excellent EMC Immunity
Full Wake-Up Capability During Failure Modes
Bus Failure Management
Support Single-Wire Transmission Mode with Ground
Offset Voltages Up to 1.5V
Thermally Protected
Do Not Disturb the Bus Line when Unpowered
Low-Current Sleep and Standby Mode with Wake-Up
Through Bus Lines
Up to 250kbps Data Rate (MAX3054)
Pin and Functionally Compatible with TJA1054
19-2687; Rev 1; 9/14
+Lead-free/RoHS-compliant package
PART TEMP RANGE DATA RATE
PIN-
PACKAGE
MAX3054ASD+ -40°C to +125°C 250kbps 14 SO
MAX3055ASD+ -40°C to +125°C
Slew control
125kbps
14 SO
MAX3056ASD+ -40°C to +125°C
Slew control
40kbps
14 SO
TXD RXD STB EN
ERR
INH
BATTERY
RTH
CANH CANL
RTL
BATT
GND
V
CC
WAKE
+5V
CAN CONTROLLER
2 3 5 6 4 1
8 11 12 9
7
10
13
14
100nF
V
BATT
+12V
CAN BUS
FAULT
TO 80V
MAX305_
14
13
12
11
10
9
8
1
2
3
4
5
6
7
BATT
GND
CANL
CANHERR
RXD
TXD
INH
TOP VIEW
V
CC
RTL
RTHWAKE
EN
STB
SO
MAX3054
MAX3055
MAX3056
MAX3054/MAX3055/
MAX3056
±80V Fault-Protected/Tolerant CAN Transceiver
Typical Operating Circuit
Pin Conguration
Ordering Information

Summary of content (18 pages)