Troubleshooting
All efforts were made to ensure that each EV kit works on the first try, right out-of-the-box. In the rare occasion that a
problem is suspected, see Table 3 to help troubleshoot the issue.
Table 3. Troubleshooting
SYMPTOM CHECK SOLUTION
GUI indicates: Hardware
not found
IstheLEDlabeledD1lred?
If yes, then the electronic fuse is in a fault state. Inspect for electrical
shorts on the PCB and make sure that the PCB is not sitting on a
conductive surface.
DoestheLEDlabeledD2l
turn off when the GUI is
running?
If not, then exit the GUI and try running it again. If D2l still does not
turn off, then exit the GUI and power cycle the board by removing
and reapplying the user-supplied power source. Try connecting the
USB cable to a different USB port on the PC and wait for a Windows
message that states that the hardware is ready to use. Run the GUI
again. If D2l still does not turn off, unplug the USB cable and reboot
the PC. Connect the USB cable and open the GUI.
AreanyoftheLEDs
illuminated?
If not, then the PCB may not be getting power from the user-
supplied power supply. Verify the power-supply bias with a voltmeter,
measuring from VCC to GND. Valid levels are 3V to 5.5V.
GUI Status indicates: Error
communicating with the
MAX31790
Slave address jumper
conguration(J5,J6)
Checkthecurrentsettingoftheslaveaddressjumpercongurations
(J5, J6) and input the resulting slave address in the Slave ID (Hex)
input box, then pressing the Set button.