Datasheet

SUPPLIER PHONE WEBSITE
Murata Electronics North America Inc. 770-436-1300 www.murata-northamerica.com
TDK Corp. 847-803-6100 www.component.tdk.com
FILE DESCRIPTION
INSTALL.EXE Installs the EV kit files on your computer
MAX5318EVKIT.EXE Application program
CDM20600.EXE Installs the USB device driver
UNINSTALL.EXE Uninstalls the EV kit software
USB_Driver_Help_200.PDF USB driver installation help file
MAX5318 Evaluation System
Evaluates: MAX5318
3Maxim Integrated
Quick Start
Required Equipment
• MAX5318EVkit
• MAXUSB2XILINXMB interface board (USB cable
included)
• WindowsXP,WindowsVistaorWindows7PCwitha
spare USB port
• Powersupply,+5VDCat600mA
• Powersupply,-5VDCat100mA
• Oscilloscope
Note: The EV system has two operation modes: stand-
alone mode and GUI mode. See the Detailed Description
of Hardware section for operation mode details.
Stand-Alone Mode Procedure
1) Verify that the jumpers on the MAXUSB2XILINXMB
interface board are in their default positions as
shown in Table 3.
2) Verify that the jumpers on the EV kit board are in
their default positions, as shown in Table 4.
3) Connect the EV kit board to the MAXUSB2XILINXMB
interface board.
4) Connect +5V DC power supply to the
MAXUSB2XILINXMB interface board between TP1
(+5V) and TP2 (GND). Keep power off.
5) Connect +5V DC power supply to the EV kit between
TP5 (+5V) and TP6 (AGND). Keep power off.
6) Connect -5V DC power supply to the EV kit between
TP7 (-5V) and TP6 (AGND). Keep power off.
7) Connect oscilloscope probe 1 to the EV kit SMA
connector J1 or test point TP1 (OUT).
8) Turn on the power supplies for the EV kit board
first. Then turn on the power supply for the
MAXUSB2XILINXMB board.
9) Observe that the DAC outputs a sine wave of 1kHz,
amplitude range is 0 to 4.096V.
10) Press and release SW3 to select between 8 sine
waveforms with different frequencies. A single LED
from LED4–LED11 is turned on, indicating a different
frequency, as shown in Table 1.
11) Press and release SW4 to select between 8 sine
waveforms with different frequencies. A single LED
from LED4–LED11 is turned off, indicating a different
frequency, as shown in Table 2.
12) Press SW5 to toggle TC/SB logic level. By default,
TC/SB = high and the DDS output is set to two’s-
complement format. If TC/SB = low, the sine wave-
form is distorted.
13) Press SW1 (RESET) to reset the MAXUSB2XILINXMB
board and the EV kit board.
Component Suppliers
MAX5318 EV Kit Files