Datasheet
MAX5392 Evaluation System
Evaluates: MAX5387/MAX5392
______________________________________________________________________________________ 13
Table 13. Jumper Configuration (continued)
*Default position.
JUMPER SHUNT POSITION EV KIT FUNCTION
JU10
1-2 U3 VDD = 1.7V (JU2 installed)
2-3* U3 VDD dependent on jumper JU1 configuration
JU11
Not installed MAX5392 HA disconnected from the U3 VDD voltage source
Installed* MAX5392 HA connected to the U3 VDD voltage source
JU12
Not installed MAX5392 LA disconnected from GND
Installed* MAX5392 LA connected to GND
JU13
Not installed MAX5392 HB disconnected from the U3 VDD voltage source
Installed* MAX5392 HB connected to the U3 VDD voltage source
JU14
Not installed MAX5392 LB disconnected from GND
Installed* MAX5392 LB connected to GND
JU15 1-2*
U3 device address = 0x58 (see Table 7)JU16 2-3*
JU17 2-3*
JU18
Not installed MAX5387 HA disconnected from the U2 VDD voltage source
Installed* MAX5387 HA connected to the U2 VDD voltage source
JU19
Not installed MAX5387 LA disconnected from GND
Installed* MAX5387 LA connected to GND
JU20
Not installed MAX5387 HB disconnected from the U2 VDD voltage source
Installed* MAX5387 HB connected to the U2 VDD voltage source
JU21
Not installed MAX5387 LB disconnected from GND
Installed* MAX5387 LB connected to GND
JU22
1-2* U4 VDD voltage connected to the U3 VDD voltage source
2-3 U4 VDD voltage dependent on jumper JU1 configuration
JU23
Not installed MAX5392 HA disconnected from the U4 VDD voltage source
Installed* MAX5392 HA connected to the U4 VDD voltage source
JU24
Not installed MAX5392 LA disconnected from GND
Installed* MAX5392 LA connected to GND
JU25
Not installed MAX5392 HB disconnected from the U4 VDD voltage source
Installed* MAX5392 HB connected to the U4 VDD voltage source
JU26
Not installed MAX5392 LB disconnected from GND
Installed* MAX5392 LB connected to GND