Datasheet

MAX5392 Evaluation System
Evaluates: MAX5387/MAX5392
4 ______________________________________________________________________________________
Table 1. Jumper Configuration for MAX5392 EV Kit Operation
*Default position.
JUMPER SHUNT POSITION EV KIT FUNCTION
JU1
1-2 VPOWER = 5V
1-3* VPOWER = 3.3V
1-4 VPOWER = 2.6V
JU2
Installed* 1.7V supply enabled
Not installed 1.7V supply disabled
JU10
1-2* U3 VDD = 1.7V
2-3 U3 VDD dependent on jumper JU1 configuration
JU11
Not installed MAX5392 HA disconnected from the U3 VDD voltage source
Installed* MAX5392 HA connected to the U3 VDD voltage source
JU12
Not installed MAX5392 LA disconnected from GND
Installed* MAX5392 LA connected to GND
JU13
Not installed MAX5392 HB disconnected from the U3 VDD voltage source
Installed* MAX5392 HB connected to the U3 VDD voltage source
JU14
Not installed MAX5392 LB disconnected from GND
Installed* MAX5392 LB connected to GND
JU15 1-2*
U3 device address = 0x58 (see Table 7)JU16 2-3*
JU17 2-3*
JU22
1-2* U4 VDD voltage connected to the U3 VDD voltage source
2-3 U4 VDD voltage dependent on jumper JU1 configuration
JU23
Not installed MAX5392 HA disconnected from the U4 VDD voltage source
Installed* MAX5392 HA connected to the U4 VDD voltage source
JU24
Not installed MAX5392 LA disconnected from GND
Installed* MAX5392 LA connected to GND
JU25
Not installed MAX5392 HB disconnected from the U4 VDD voltage source
Installed* MAX5392 HB connected to the U4 VDD voltage source
JU26
Not installed MAX5392 LB disconnected from GND
Installed* MAX5392 LB connected to GND