Datasheet

MAX6001–MAX6005
Low-Cost, Low-Power, Low-Dropout,
SOT23-3 Voltage References
_______________________________________________________________________________________
9
Typical Operating Characteristics (continued)
(V
IN
= +5V for MAX6001–MAX6004, V
IN
= +5.5V for MAX6005; I
OUT
= 0; T
A
= +25°C; unless otherwise noted.) (Note 6)
I
OUT
40µA/div
+25µA
-25µA
V
OUT
20mV/div
10µs/div
MAX6001
LOAD-TRANSIENT RESPONSE
MAX6001-19
I
OUT
= ±25µA, AC-COUPLED
I
OUT
50µA/div
V
OUT
50mV/div
20µs/div
MAX6005
LOAD-TRANSIENT RESPONSE
MAX6001-20
V
IN
= 5.5V, I
OUT
= ±25µA, AC-COUPLED
V
IN
2V/div
V
OUT
2V/div
10µs/div
MAX6005
TURN-ON TRANSIENT
MAX6001-21
I
OUT
500µA/div
V
OUT
200mV/div
20µs/div
MAX6005
LOAD-TRANSIENT RESPONSE
MAX6001-23
V
IN
= 5.5V, I
OUT
= ±500µA, AC-COUPLED
V
IN
200mV/div
V
OUT
100mV/div
2.5µs/div
V
IN
= 5V ±0.25V, AC-COUPLED
MAX6001
LINE-TRANSIENT RESPONSE
MAX6001-24
Note 6: Many of the
Typical Operating Characteristics
of the MAX6001 family are
extremely similar. The extremes of these characteristics are found in the
MAX6001 (1.2V output) and MAX6005 (5.0V output) devices. The
Typical
Operating Characteristics
of the remainder of the MAX6001 family typically
lie between these two extremes and can be estimated based on their output
voltage.