Datasheet
MAX6006–MAX6009
1µA SOT23 Precision Shunt
Voltage Reference
2
Maxim Integrated
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS—MAX6006
(T
A
= -40°C to +85°C, unless otherwise noted. Typical values are at T
A
= +25°C.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
Operating Current (OUT to GND) ......................................20mA
Forward Current (GND to OUT) ..........................................20mA
Continuous Power Dissipation (T
A
= +70°C)
3-Pin SOT23 (derate 4mW/°C above +70°C)..............320mW
8-Pin SO (derate 5.48mW/°C above +70°C)...............471mW
Operating Temperature Range ...........................-40°C to +85°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Soldering Temperature (reflow) .......................................+260°C
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
MAX6006A (0.2%) 1.2475 1.2500 1.2525
Reverse Breakdown Voltage V
R
T
A
= +25°C,
I
R
= 1.2µA
MAX6006B (0.5%) 1.2438 1.2500 1.2563
V
Minimum Operating Current I
RMIN
V
R
change < 0.2% from V
R
at I
R
= 1.2µA 0.5 1.0 µA
I
R
= 1.2µA to 200µA 1.0
Reverse Breakdown Change
with Current
I
R
= 200µA to 2mA 2.0
mV
Reverse Dynamic Impedance I
R
= 1.2µA to 2mA (Note 2) 1.5 Ω
Low-Frequency Noise I
R
= 1.2µA, f = 0.1Hz to 10Hz 30 µV
P-P
MAX6006A 30
Temperature Coefficient
(Note 3)
TC I
R
= 1.2µA
MAX6006B 75
ppm/°C
Long-Term Drift 1000h at T
A
= +25°C 150 ppm
Thermal Hysteresis (Note 4) 200 ppm