Datasheet
MAX6033
Ultra-High-Precision SOT23 Series
Voltage Reference
2
Maxim Integrated
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS—V
OUT
= 2.500V
(V
IN
= 5V, C
OUT
= 0.1µF, I
OUT
= 0A, T
A
= T
MIN
to T
MAX
, unless otherwise specified. Typical values are at T
A
= +25°C.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
IN to GND ...............................................................-0.3V to +13V
OUTF, OUTS to GND................................................-0.3V to +6V
Continuous Power Dissipation (T
A
= +70°C)
6-Pin SOT23 (derate 9.1mW/°C above +70°C)............727mW
Operating Temperature Range .........................-40°C to +125°C
Storage Temperature Range .............................-65°C to +150°C
Maximum Junction Temperature .....................................+150°C
Lead Temperature (soldering, 10s) .................................+300°C
Soldering Temperature (reflow)
RoHS-Compliant Packages ..........................................+245°C
Packages Containing Lead(Pb)....................................+240°C
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
MAX6033A
2.4990 2.5000 2.5010
MAX6033B
2.4950 2.5000 2.5050
Output Voltage V
OUT
T
A
= +25°C
MAX6033C
2.4975 2.5000 2.5025
V
MAX6033A
-0.04 +0.04
MAX6033B
-0.2 +0.2
Output-Voltage Accuracy T
A
= +25°C
MAX6033C
-0.1 +0.1
%
T
A
= -40
o
C to +85
o
C
1.5 7
MAX6033A
T
A
= -40
o
C to +125
o
C
2.5 10
T
A
= -40
o
C to +85
o
C
310
MAX6033B
T
A
= -40
o
C to +125
o
C
715
T
A
= -40
o
C to +85
o
C
620
Output Voltage Temperature
Coefficient
TCV
OUT
MAX6033C
T
A
= -40
o
C to +125
o
C
10 40
ppm/°C
Input Voltage Range V
IN
Inferred from line regulation specification
2.7 12.6
V
T
A
= +25°C
325
Line Regulation
∆V
OUT
/
∆V
IN
2.7V ≤ V
IN
≤ 12.6V
T
A
= -40°C to +125°C
50
µV/V
T
A
= +25°C
0.001 0.05
Load Regulation
∆V
OUT
/
∆I
OUT
-100µA ≤ I
OUT
≤
15mA
T
A
= -40°C to +125°C
0.1
mV/mA
V
OUT
= 0.1%, I
OUT
= 1mA
0.02 0.2
T
A
= -40
o
C to +85
o
C
0.3 0.4
Dropout Voltage (Note 2) V
DO
V
OUT
= 0.1%,
I
OUT
= 10mA
T
A
= - 40
o
C to + 125
o
C
0.5
V
T
A
= +25
o
C
40 60
T
A
= -40
o
C to +85
o
C
75
Quiescent Supply Current I
IN
T
A
= -40
o
C to +125
o
C
85
µA
V
OUT
= 0V
90
Output Short-Circuit Current I
SC
V
OUT
= V
IN
-2
mA
0.1Hz ≤ f ≤ 10Hz
16
µV
P-P
Output-Voltage Noise e
n
10Hz ≤ f ≤ 1kHz
12
µV
RMS
Turn-On Settling Time t
ON
V
OUT
settles to ±0.01% of final value
500
µs
Temperature Hysteresis (Note 3)
150
ppm
Long-Term Stability ∆t = 1000hr
40
ppm