Datasheet
Figure 10. Monitoring Other System VoltagesFigure 9. RESET Valid to Ground Circuit
Bold indicates standard version.
PP = push-pull, OD = open drain.
*WDO deasserts when MR is pulled low. See the Standard- vs. A-Version Comparison section for the differences on WDO.
SUFFIX
RESET
THRESHOLD (V)
L 4.63
M 4.38
T 3.08
S 2.93
R 2.63
Z 2.32
Y 2.19
PART
RESET
PP LOW
RESET
PP HIGH
RESET
OD-LOW
WDI WDO
PFI,
PFO
RST_IN1,
RST_IN2
MAX6701
✔
— —
✔ ✔ PP
—
✔
MAX6701A*
✔
— —
✔ ✔ PP
—
✔
MAX6702 —
✔
—
✔ ✔ PP
—
✔
MAX6702A* —
✔
—
✔ ✔ PP
—
✔
MAX6703 — —
✔ ✔ ✔ OD
—
✔
MAX6703A* — —
✔ ✔ ✔ OD
—
✔
MAX6704
✔ ✔
—
✔
—
✔ PP
—
MAX6705
✔
— —
✔ ✔ PP ✔ PP
—
MAX6705A*
✔
— —
✔ ✔ PP ✔ PP
—
MAX6706 —
✔
—
✔ ✔ PP ✔ PP
—
MAX6706A* —
✔
—
✔ ✔ PP ✔ PP
—
MAX6707 — —
✔ ✔ ✔ OD ✔ OD
—
MAX6707A* — —
✔ ✔ ✔ OD ✔ OD
—
MAX6708
✔ ✔
— — —
✔ PP
—
V
CC
PFI
MR
PFO
RESET
0.9V
3.3V
MAX6704–
MAX6708
I/O
SUPPLY
CORE
SUPPLY
µP
RESET
(RESET)
() ARE FOR MAX6704/MAX6706(A)/MAX6708 ONLY.
R1 (100kΩ)
RESET
MAX6701(A)
MAX6704
MAX6705(A)
MAX6708
www.maximintegrated.com
Maxim Integrated
│
10
MAX6701-08/
MAX6701A-03A/
MAX6705A-07A
Low-Voltage, SOT23 µP Supervisors with Power-Fail
In/Out, Manual Reset, and Watchdog Timer
Threshold Sufx Guide
Selector Guide