Datasheet

National Instruments GPIB card and cable
Thermonics T-2800 precision temperature forcing system
Perl script for controlling the FPGA development kit and measurement equipment
Windows PC
INL, DNL, and TUE are the most important specifications for PLC and other process control systems. The
MAX15500 is highly flexible and configurable to meet the needs of various applications. The data was taken
at +25°C. In the following pictures, the DNL, INL, and TUE for the first 320 DAC codes are shown as 0
because codes 0 to 320 are in the deadband (0 to 0.02V) of the MAX5134.
Measurements of DNL, INL, and TUE for the -10V to +10V voltage output mode, with 20% overrange are
shown in Figure 3, Figure 4, and Figure 5, respectively.
Figure 3. DNL for -10V to +10V output range, with 20% overrange.
Figure 4. INL for -10V to +10V output range, with 20% overrange.