Figure 11. Output error for -20mA to +20mA output range, with 20% overrange.
Measurements of DNL, INL, and TUE for the 0 to 20mA current output mode, with 20% overrange are shown
in Figure 12, Figure 13, and Figure 14, respectively.
Figure 12. DNL for 0 to 20mA output range, with 20% overrange.
Figure 13. INL for 0 to 20mA output range, with 20% overrange.