Figure 14. Load step at 5V (100%, 50%, 100% of 3A), 57V input, 3.3V at 1.8A. CH1: 3.3V rail, CH2: 5V rail,
CH3: 5V rail current.
Other Options of Circuit Operations
Besides the 3.3V/1.8A, 5V/3A opto feedback isolated, the Pasadena can support other circuit operations,
such as the following:
1. Opto single output of 3.3V/6A
2. Opto single output of 5V/4A
3. Optoless single output of 3.3V/6A
4. Optoless single output of 5V/4A
5. Optoless dual output 3.3V/1.8A and 5V/3A
For the implementations of each opto, contact factory for more details.