Specifications
Adjusting the red timers 
Measure the distance between ‘WAIT HERE’ signs, or the ‘WAIT HERE’ sign and datum point, 
(see page 7), and use the table below: 
Distance (metres)   0   50   100   150   200   250  300 
All-Red time (seconds) 
 5   10   15  
20  25  30 
NOTE: On some controllers the All-Red switch may be marked in metres and the equipment converts to 
seconds automatically. 
Method of selection 
and values may differ 
If the site is on a steep gradient, you may need to increase the indicated 
All-Red value for the uphill direction incrementally until vehicles clear safely. 
If there are large numbers of slow-moving vehicles that have difficulty in 
clearing the works before the lights have changed, increase indicated values 
of the relevant All-Red settings incrementally until vehicles clear safely. 
9 