Disconnect the power by turning off the circuit breaker or by removing the appropriate fuse at the
fuse box. Turning the power off using the light switch is not sufficient to prevent electrical shock.
Step 1: Make sure the circu
it breaker that supplies power to the fixture is turned off.
Step 2: Remove lens or diffusion cover on the lighting fixture.
Step 3: Remove the existing T8/T12 florescent tubes.
Step 4: Remove the ballast cover and identify the line and neutral wires running from the breaker
box to the ballast and confirm the power is off using a voltmeter.
Step 5: Ensure that the fixture contains non-shunted G13 bi-pin
lamp holders. If not, remove
Shunted lamp holders and install non-shunted lamp holders.
Step 6: Cut the line and neutral wires at the ballast, as well as all remaining wires
at the ballast (see Figure 1).
Step 7: Remove Ballast (and starter if present). Dispose of removed ballast in
accordance with government regulations in your area.
Step 8: For single-ended wiring, please see Figure 2a, 2b, 2c or 2d.
Step 9: Reinstall the ballast cover to hide all wire.
Step 10: IMPORTANT: Peel off the provided caution label and install on a
visible location inside the fixture.
Installation & Operation - Single-Ended Wiring
Figure 2a
Figure 2b
Figure 2c
Figure 2d
Operating Instructions L13T8EX4xx & L18T8EX4xx Series
MaxLite External LED T8 - 4FT
®
Or
DC Lin (370mA) - Vin (45V)
DC Lin (370mA) - Vin (45V)
Kit Model:
L18T8EX4xx(DDR2L18) or L18T8EX4xx(DDR4L18)
Lamp Model: L18T8EX4xx “xx” = CCT: 35, 40 or 50
DC Lin (270mA) - Vin (45V)
DC Lin (270mA) - Vin (45V)
Kit Model:
L13T8EX4xx(DDR2L13) or L13T8EX4xx(DDR4L13)
Lamp Model: L13T8EX4xx “xx” = CCT: 35, 40 or 50