User's Manual

4
To receive maximum performance from your radio and battery pack, periodically completely discharge and
recharge the battery pack.
Status Indicators and Audible Alert Tones
Your S
P-6102 has a sophisticated microprocessor control which provides a series of audible alert tones.
Upon initial power up, a quick melody indicates that the self-test of the microprocessor functions has been
completed satisfactorily. A series of tones may be sounded with any of the following conditions:
· Attempt to transmit on a channel set for receive only
· Attempt to transmit on a channel that is already in use when busy channel lockout has been programmed
into the radio *
· Transmitting time has exceeded time-out timer programmed length *
· Low battery condition
· Selecting a channel with no programmed frequency
* Indicates a function that is initially programmed into the radio by your Maxon Dealer.
NOTE: All audible tones can be programmed off for silent operation.
Status Decription LED color LCD Indication Audible Tone
Normal Power On - Ready N/A Channel number Melody
Call Received Orange Channel number N/A
Correct Call Green Channel number N/A
Busy Channel Orange Channel number N/A
Transmit Red Channel number N/A
Transmit not
allowed
Red
Flashing
Alternating UL/Channel
number
Two beeps
Scanning Normal Scan mode Green
Flashing
Group number or channel
number (remove)
N/A
Priority Scan Mode Green
Flashing
Group number or channel
number (remove)
Priority Look
BackScan Mode
Green
Flashing
PS/Channel number N/A
Scan
Edit
Edit scan list N/A Scan N/A
Priority
Edit
Edit Priority
channel
N/A Pscn N/A
Warning Low Battery Red
Flashing
Low_-BATT 3 beeps
Busy Channel
lockout
orange Busy-Lock Single beep
TX Inhibit N/A PENALTY
Two beeps
Time-out-timer N/A TIME-OUT
Single beep/3
beeps repeated
Error
Unlock N/A UNLOCK Two beeps
Operation Mode
This section provides general descriptions of the operating modes of the S
P-6102 Radio.
Power Off Mode
The S
P-6102 shall enter Off mode when the On/Off Volume knob is rotated to the most counter-clockwise
position, beyond the detent. Upon entering Off mode, the radio shall store its current channel(if Power On
Channel function is disabled via PC programmer).
Power On Mode
The S
P-6102 shall enter Power-On mode when the On/Off Volume knob is rotated clockwise beyond the
detent. Upon entry of the Power-On mode, the radio shall perform the 5 times power-on alert to indicate
that it has been turned on.