37. Use a forklift or equivalent lifting device
to lift platform and line it up with attaching
points on the LH runner (FIG. 44-2) and
RH runner.
36. To reinstall opening/closing cylinder,
do the opening/closing cylinder
replacement steps in the OPENING/
CLOSING CYLINDER REPLACEMENT
procedure in this manual.
Avoid making sharp bends in
wiring.
CAUTION
NOTE: MAXON recommends using
dielectric grease on all electri-
cal connections.
35. Connect runner switch cable
to exible cable near bottom of
runner as shown in FIG. 44-1.
Then, use clamps and lock
nuts to fasten molded portion of
connectors to runner (FIG. 44-1).
34. Position exible cable and twin
hydraulic hoses in the channel at
bottom of runner (FIG. 44-1).
FLEXIBLE CABLE
CONNECTOR
FIG. 44-1
CLAMP
LOCK NUT
HOSES
SCREW
RUNNER SWITCH
CABLE
CONNECTOR
FIG. 44-2
NOTE: If replacing LH runner, skip
steps 34, 35 and 36.
REPLACING PARTS