Specifications

A Remote Automated Water Quality Stream Gauging System Design 22
22
8. APPENDICES
Appendix 1 – Modem Setup
Wavecom Fastrack GSM modem
1. Enter the settings
AT+IPR=9600 E0 Q1 S0=2 <ENTER>
2. Save the configuration
AT&W <ENTER>
ModMax 3G Data Modem
1. Set auto soft reset to a scheduled interval (1440 = Daily)
AT$$RESET=1440
2. Check reset value
AT$$RESET?
3. Set CSD Service Type AT+CBST= (speed, data circuit type, transfer type)
AT+CBST=7,0,1
4. Turn Circuit 109 on for CSD Service
AT&C1
5. Set Modem to Auto Answer after 2 seconds
ATS0=2
6. Set Baud Rate
AT+IPR=9600
7. Set modem to suppress result codes
ATQ1
8. Turn Echo 0ff
ATE0
9. Save Configuration Changes to user profile 1
AT&W1
10. Set Profile 1 as the default user profile (loaded automatically after power outage or reset)
AT&F1