Modem Options 
Modem Option for data communication 
ACC-513E and ACC-514E are new kinds of internal option-modems, which are applied to SD-
170E series to increase capability for data application. The goal of internal modem is to improve 
the efficiency for data transmission and provide maximum flexibility for user application. In former 
case, the most obvious method of increasing the efficiency is to maximize the data signaling 
speed in the limited channel bandwidth. But, FSK, called direct FM modulation, has very wide 
transmission bandwidth requirement. To solve this problem, MaxonCIC supplies GMSK 
(Gaussian Filtered Minimum Shift Keying) internal option-board. In latter case, to improve quality 
of service, some of service provider (or user) wants to apply new radio to their existing system 
without additional investment to establish new system even if it‟s audio system. But, data 
application can‟t be directly applied in audio system because of its spectra characteristic. 
Generally, spectra of data have wider bandwidth than audio. So, direct application of data is not 
matched with audio system and its application. For instance, if sub-audio(Tone) SQ system is 
applied to data application, its frequency spectra conflicts with that of sub-audio. Moreover, if 
inputted data is filtered by audio filter circuit to avoid this problem, some of that will be broken. 
Therefore, to get over these problems and provide maximum flexibility, Maxon prepares FFSK 
(Fast Frequency Shift Keying) internal option-board. 
Our internal modem option boards consist of Slave MCU, Modem IC, and extra circuitry. These 
option-boards directly communicate with DTE (Data Terminal Equipment) to send and receive the 
meaningful data through the DB-15 connector on digital board of SD-170E. These are designed to 
accept RS232 serial data format and also capable of high speed wireless data-transmission 
between two or more devices. More detail information for modem option boards is given in 
technical manual for ACC-513/514. Moreover, dealer will help you define a TX On/Off Delay time, 
RX On Delay time, Baud Rate, Modem Enabled, Modem Baud Rate, Data flow control, and Test 
Mode. 
Table for modem speed 
Channel Space 
DTE Baud Rate 
Modem Baud Rate 
Narrow (12.5KHz) 
1200 
1200 
2400 
2400 
Standard (25KHz) 
1200 
1200 
2400 
2400 
4800 
4800 
Available Baud rate for FFSK modem 
Channel Space 
DTE Baud Rate 
Modem Baud Rate 
Narrow (12.5KHz) 
4800 
4800 
Standard (25KHz) 
4800 
4800 
9600 
9600 
 Available Baud rate for GMSK modem 
GPS option board 
As one of the methods to satisfy various requests for user application, SD-170E supports GPS 
data handling. That may help your implementation for system related to GPS. Nevertheless, if it‟s 
not enough for each your application, received position data from GPS module placed in SD170E 
can  be  reprocessed by  your  own  application.  ACC-515E is  GPS  module  for SD170E which 
releases some of 11 different output data according to NMEA-0183 format. Moreover, it can be 
also selected by user, but it should be processed by user‟s application. Received data from ACC-
515E will be released via DB-15  connector of SD-170E or/and  transmitted to other system 
through installed modem. More detailed information for GPS  option board is given in technical 
manual for ACC-515E. 